Age | Commit message (Collapse) | Author |
|
The addition of init_v3 accidentely changed default values for soft
resetting Ethos-U. Restore the default parameters to non-secure, user
mode for init_v1 and init_v2 and also make sure to check return value
from ethosu_soft_reset.
Change-Id: If7377f11ad1db7ff988fdcba03320a54e6e0c0c1
|
|
Change-Id: I8ca309ea4e5885865d5c9cf848500f45f83e08a2
|
|
Storing PMU counters in shadow variables, in case the PMU was powered
off or soft reset.
Change-Id: I64ccf3fb6195f9be2d8315891ec612bb75404885
|
|
The ETHOSU is soft-reset only if the previous job failed or if
the current privilege level is not user or if the current security
level is not secure.
Change-Id: Id10b96058d67805d179ac693537606d55e10379b
|
|
Change-Id: Ie4186f5ab881d5c13021299404322ff582180d26
|
|
Change-Id: I84754f316ce940917516cb7f5c59189f523d4095
|
|
Change-Id: I1145834000ff81d6e497a8fa77bf997478a80372
|
|
Turn the IRQ initialization around, to have the application define the
interrupt handler and expose the driver routine that is to be called
when that happens.
Change-Id: Idbfba1b1d1a1eaf6678ee16e9583c496eb2287ed
|
|
Change-Id: I541862775031c21e6483f26446a29dfe452382ab
|